Measuring a power rail to ground is a useful first check when a board draws excessive current or a supply rail is missing. The challenge is interpreting the number correctly.
Measure with the board unpowered
Disconnect power and discharge stored energy. Select resistance mode and measure between the target rail and its appropriate ground reference.
Expect different rails to behave differently
High-current CPU, GPU and core-voltage rails can naturally have very low resistance. Other rails may measure much higher. There is no single resistance threshold that proves a short on every board.
Watch the reading over time
Capacitors can charge from the meter’s test current, causing the displayed resistance to rise. A changing reading therefore may reflect normal capacitive behavior rather than an intermittent connection.
Use the result to choose the next test
An unusually low rail may justify diode-mode comparison, sectional isolation or carefully controlled current-limited injection. Do not inject voltage until the rail’s safe operating range is known.
Compare real measurements instead of guessing.