SMPS · STARTUP FAILURE

SMPS Not Starting: A Systematic Troubleshooting Guide

When a switch-mode power supply stays completely dead, separate the input, startup, switching and protection stages before replacing parts.

An SMPS that does not start can fail before the controller receives power, during controller startup, in the switching stage or because a protection condition immediately shuts the supply down.

Check the input path

Inspect the fuse, input protection, rectifier and high-voltage DC bus. If the bus is absent, troubleshooting should remain in the input and rectification section rather than moving to the secondary side.

Check controller startup supply

Many PWM controllers require a startup voltage on their VCC pin before switching begins. A failed startup resistor, auxiliary supply fault, leaky capacitor or excessive load can prevent this voltage from reaching the required threshold.

Look for switching activity

If the controller supply is valid, determine whether gate-drive or switching activity is present using correctly rated and safely referenced equipment. No drive and drive that starts then stops point to different diagnostic paths.

High-voltage warning: The primary side of an offline SMPS can remain at lethal potential. Oscilloscope grounding errors can also create a direct short to mains. Use appropriate isolation and differential measurement practices.

Consider protection and secondary faults

A shorted secondary rectifier, overloaded output or feedback problem can cause repeated startup attempts. Check whether the supply is truly inactive or cycling rapidly under protection.