A short circuit often appears as excessive current draw, a supply that collapses, a protection circuit that activates or a device that will not start. The key is to identify which rail is affected before trying to locate the exact component.
Start with power removed
Measure resistance between the suspected supply rail and ground. Compare several rails if possible. Some modern low-voltage rails naturally have low resistance, so a low reading alone does not prove a short.
Separate the circuit into sections
Use inductors, zero-ohm resistors, fuses and connectors as natural boundaries. Measurements on both sides of these points can help determine which section contains the abnormal load.
Use a current-limited supply carefully
When appropriate for the circuit, controlled voltage injection with a strict current limit can help localize a short by identifying the component or area that heats. Never inject voltage into an unknown rail without first understanding its normal operating voltage and connected devices.
Confirm before replacing anything
Once a suspicious component is found, verify the diagnosis with diode-mode, resistance or isolation measurements. Heating can identify the location, but it does not always prove that the warm component is the original cause.
Document short-circuit diagnosis systematically.